How this calculation works
The chart method selects the published room-area band for an eight-foot ceiling. This implementation adjusts that base for sun exposure, then adds the stated extra-occupant and kitchen allowances. Legacy mode separately reproduces the old site’s 25 Btu/h per square foot heuristic, applies exposure after its occupant addition and rounds upward to the next 500 Btu/h. The methods are not represented as equivalent.
Chart estimate = base band × exposure + 600 × max(occupants−2,0) + kitchen additionA worked example
For a 200 ft² room, average exposure, one occupant and no kitchen adjustment, the chart base is 6,000 Btu/h. The archived 25-per-square-foot heuristic instead gives 5,000 Btu/h. That difference illustrates why a rough area multiplier is not the same reference as a published band table.
Good to know
Preliminary room-AC reference, not a whole-building heat-load calculation or equipment approval. The chart covers 100–2,500 ft² and assumes an eight-foot ceiling. Climate, insulation, humidity, infiltration and geometry need more complete assessment. Capacity Btu/h is not electricity use.
Reference: ENERGY STAR: properly sized room air conditioners (opens in a new tab) ↗
Cooling capacity is a rate
Btu is an energy unit; Btu per hour is a cooling-capacity rate. A room-AC sizing result in Btu/h is therefore not the same as electricity consumed over a billing period. Cooling output and electrical input are related through equipment performance, which is not inferred from these few room inputs.
The ENERGY STAR lookup uses floor-area bands for an eight-foot ceiling. This implementation uses lower-inclusive and upper-exclusive bands, with the final 2,500 ft² endpoint accepted in the last band. That convention is visible so an area right at a boundary does not depend on an unexplained rounding choice.
Keep the published chart separate from the archived multiplier
The older site multiplied area by twenty-five and added an occupancy allowance. That rough heuristic is still available as a clearly labeled comparison, but it is not described as the ENERGY STAR chart. For a two-hundred-square-foot example the two methods can produce different capacities even before exposure adjustments.
The percentage calculator explains how a ten-percent sun adjustment changes a stated base. The chart branch applies exposure to its base first and adds occupant and kitchen allowances afterward. These limited adjustments do not account for a building envelope, humidity loads, climate or every heat source. A larger unit is not automatically a better humidity-control solution.
A few questions, answered
Is Btu/h the same as electricity use?
No. It is a rate of cooling capacity, not an electrical energy bill.
Is the archived area multiplier the published chart?
No. They are separate methods and can disagree.
Does this size an entire building?
No. It is a preliminary room-AC reference comparison.